World’s first Colour-and-Gloss Bench-top spectrophotometer with versatile horizontal or top-port alignment. Innovative measurement technology and best price/performance ratio in the field of reflectance and transmission colour measurements.
Model
Spectrophotometer CM-3600A
Illumination/observation system
Reflectance; di:8°, de:8° (diffused illumination, 8-degree viewing), equipped with simultaneous measurement of SCI (specular component included) / SCE (specular component excluded); Conforms to CIE No.15, lSO7724/1, ASTM E-1164, DIN 5033 Teil7 and JIS Z8722 condition C standard. Transmittance : di:0°, de:0° (diffused illumination, 0-degree viewing); Conforms to CIE No.15, ASTM E-1164 and DIN 5033 Teil7 standard.
Light-receiving element
Silicon photodiode array (dual 40 elements)
Spectral separation device
Diffraction grating
Wavelength range
360 to 740 nm
Wavelength pitch
10 nm
Half bandwidth
Approx. 10 nm
Reflectance range
0 to 200%; Resolution: 0.01%
Sphere size
Ø152 mm
Light source
Four pulsed xenon lamps
Minimum interval between measurements
Normal SCI/ SCE measurement: 4 sec. UV-cut / UV-adjusted measurement: 5 sec. Transmittance measurement: 3 sec.
Measurement/illumination areas
Reflectance: Changeable between LAV, MAV, and SAV LAV: Ø25.4 mm / Ø30 mm MAV: Ø8 mm / Ø11 mm SAV: Ø4 mm / Ø7 mm Transmittance: Approx. Ø17 mm
Repeatability
When white calibration plate is measured 30 times at 10-sec. intervals after white calibration has been performed: Spectral reflectance: Standard deviation within 0.1% Colorimetric values: Standard deviation within ΔE*ab 0.02
Inter instrument agreement
Mean ΔE*ab 0.15 (LAV/SCI) Average for 12 BCRA Series II color tiles compared to values measured with master body
UV adjustment
Instantaneous numerical adjustment
UV cut filters
400 nm cutoff and 420 nm cutoff
Transmittance chamber
Width: 133 mm, Depth: Approx. 50 mm; Measurement diameter: Approx. 17 mm Transmission sample holder (optional accessory): Sample holder for both plate-shaped and liquid samples (removable); Liquid samples not measurable with CM-3610A.
Interface
USB 1.1
Power
AC 100 to 240V 50/60Hz (using included AC adapter)
Operating temperature/humidity range
13 to 33°C, relative humidity 80% or less (at 35°C) with no condensation
Storage temperature/humidity range
0 to 40°C, relative humidity 80% or less (at 35°C) with no condensation
Size (W × H × D)
244 × 205 × 378 mm
Weight
11.5 kg
Standard accessories
White Calibration Plate, Target Mask (Ø4 mm), Target Mask (Ø8 mm), Target Mask (Ø25.4 mm), Zero Calibration Box, AC Adapter, Dust Cover, Accessory Case, USB Cable (3 m)
Optional accessories
SpectraMagic™ NX, Transmittance Specimen Holder, Cell (2mm)/(10mm)/(20mm), Plastic Cell (2mm)/(10mm)/(20mm), Transmittance Zero Calibration Plate, USB Cable (5 m)
Horizontal aligned Spectrophotometer for reflectance & transmission